Model No. Application Electric System Output Rating Cooling Method Characteristics / Features
RTI- 400-750 Commuter Train 750 V DC 2 × 200 kW/700
A/500 V AC
Water cooling Unit of Control: 1C1M
Circuit contiguration: 2
Level , 3 phse , voltage
type VVVF Inverter

Traction Drives

RTI-400-750

Description Value
Dimensions (L × W × H) 2065 × 1018 × 451 mm
Max . Weight 280 kg
Technology1C1M
Input voltage range-
Vlow trip 450 V
Vmin block 500 V (T.E=0)
Vmin full performance 750 V
Vmax full performance 900 V
Vhigh trip 1050 V
Input current range 0-700 A
Output voltage range at input 750 VDC 0-585 V
Output current range at input 750 VDC 0-660 A
Frequency range 0-150 Hz
Type of IGBT 1700 V/600 A
Typical efficiency over load cycle 98%
Cooling Water Cooled
Cooling capacity 25 l/min
Protection Class IP55